Posted on

by

in

HP Raid-Controller

next toy

 

 

After a reboot all works as expected and all the devices show also up with lsscsi.

root@debian:~# lspci -knn
...
04:00.0 RAID bus controller [0104]: Hewlett-Packard Company Smart Array G6 controllers [103c:323a] (rev 01)
        Subsystem: Hewlett-Packard Company Smart Array P410i [103c:3245]
        Kernel driver in use: hpsa
14:00.0 RAID bus controller [0104]: Hewlett-Packard Company Smart Array G6 controllers [103c:323a] (rev 01)
        Subsystem: Hewlett-Packard Company Smart Array P212 [103c:3241]
        Kernel driver in use: hpsa
root@debian:~# lsscsi 
[0:0:0:0]    storage HP       P410i            3.52  -       
[0:0:0:1]    disk    HP       LOGICAL VOLUME   3.52  /dev/sda
[1:0:0:0]    storage HP       P212             3.52  -       
[1:2:0:0]    tape    HP       Ultrium 2-SCSI   T65D  /dev/st0
[3:0:0:0]    cd/dvd  ATAPI    DVD A  DH16AAS   JHE5  /dev/sr0

 

Monitoring:

cciss-vol-status

 

und

 

hpacucli 

 

https://www.linux-survival-blog.de/2012/06/ubuntu-12-04-hpacucli-installieren-hp-array-configuration-utility-cli/

 

root:~# ./hpraidinfo

Smart Array P410 in Slot 1
Bus Interface: PCI
Slot: 1
Serial Number: PACCR9VYJIN7
Cache Serial Number: PAAVP9SZ832X
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: C
Firmware Version: 2.72
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Surface Scan Mode: Idle
Queue Depth: Automatic
Monitor and Performance Delay: 60  min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 100% Read / 0% Write
Drive Write Cache: Disabled
Total Cache Size: 512 MB
Total Cache Memory Available: 400 MB
No-Battery Write Cache: Disabled
Battery/Capacitor Count: 0
SATA NCQ Supported: True

Smart Array P410 in Slot 1
array A
logicaldrive 1 (149.0 GB, RAID 1, Interim Recovery Mode)
Smart Array P410 in Slot 1
array A
physicaldrive 2I:0:5 (port 2I:box 0:bay 5, SATA, 160.0 GB, Failed)
physicaldrive 2I:0:6 (port 2I:box 0:bay 6, SATA, 160.0 GB, OK)

root#
root# ./hpraidstatus

Smart Array P410 in Slot 1
Controller Status: OK
Cache Status: OK

logicaldrive 1 (149.0 GB, RAID 1): Interim Recovery Mode
physicaldrive 2I:0:5 (port 2I:box 0:bay 5, 160.0 GB): Failed
physicaldrive 2I:0:6 (port 2I:box 0:bay 6, 160.0 GB): OK

 

http://hwraid.le-vert.net/wiki/SmartArray#a3.2.hpacucli